The SIKA TP M 165S temperature calibrator can be used everywhere, including on-site in workshops, test and measurement rooms as well as laboratories. The SIKA TP M 165S temperature calibrator covers a broad spectrum of industries with diverse applications.

Price and delivery time will be given on request
Stability ±0.05°C
Resolution 0.01°C in the range of -9.99...99.99°C
Resolution 0.01°C in the range of -9.99...99.99°C
Block Ø 60 mm / depth 170 mm

The SIKA TP M 165S temperature calibrator can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. The SIKA TP M 165S temperature calibrator covers a broad spectrum of industries with diverse applications.

The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and width can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern.

Black body function

A patented infrared calibration sleeve is used to calibrate IR pyrometers or thermal imaging cameras. The special surface structure and the asymmetrical shapes create a „cavity radiator“ with an emission factor of 0.9994, prevent the reflection of interference radiation and emit the required temperature in an ideal form. The pyrometer is simply held at the specified distance above the measurement opening, thereby forming the desired measurement area on the bottom for the calibration to be performed. A support base can be fitted directly on the unit.

Micro bath function

The use of calibration liquids offers certain advantages if temperature sensors with an unusual shape and size are to be tested. The test item is immersed directly into the liquid without an insulating air gap, resulting in direct temperature contact between the calibrator and the test item. The liquid, such as silicone oil, is chosen depending on the calibration temperature required. The continuous adjustment of the magnetic stirrer together with the removable sensor basket agitates the calibration liquid to create a large measuring zone. Furthermore, the sensor basket guarantees unhindered stirring and helps protect the tank floor.

Request an offer

RECEIVE A QUOTE WITHIN 3 HOURS ON BUSINESS DAYS

  • 1. Product request

    • or
  • 2. Your information

  • This field is for validation purposes and should be left unchanged.

GMS_Instruments_Delivery

Want more information?

Get in touch with Bart our SIKA specialist

Bart

Bart de Haan

Managing Director

GMS-Instruments-brochure-2024

Product catalog

General contact

Driemanssteeweg 190
3084 CB Rotterdam
The Netherlands
GMS-Instruments-hq