SIKA

TP37 166 E Temperature Calibrator

The SIKA TP37 166 E premium temperature calibrators can be used everywhere, including on-site in workshops, test and measurement rooms as well as laboratories. The SIKA TP premium series covers a broad spectrum of industries with diverse applications.The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the…

Price and delivery time will be given on request

The SIKA TP37 166 E premium temperature calibrators can be used everywhere, including on-site in workshops, test and measurement rooms as well as laboratories. The SIKA TP premium series covers a broad spectrum of industries with diverse applications.

The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and width can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flash points or outgassing are of no concern.

Black body function

A patented infrared calibration sleeve is used to calibrate IR pyrometers or thermal imaging cameras. The special surface structure and the asymmetrical shapes create a „cavity radiator“ with an emission factor of 0.9994, prevent the reflection of interference radiation and emit the required temperature in an ideal form. The pyrometer is simply held at the specified distance above the measurement opening, thereby forming the desired measurement area on the bottom for the calibration to be performed. A support base can be fitted directly on the unit.

Surface temperature function

Surface temperature sensors are calibrated using special sleeves that are fitted vertically with the required contact force. Switching calibration control to the external reference sensor creates the best possible temperature reference point on the surface of the sleeve. The reference sensor is located directly beneath the abutting face of the sleeve. The sleeve is designed in such a way that the best temperature homogeneity is achieved in the centre of the abutting face. The special design of the abutting face enables good thermal contact. There is no need to use a thermally conductive paste or other thermal conduction aids.

Datasheet SIKA Temperature Calibrators Datasheet_SIKA_Temperature_Calibrators.pdf

Request an offer

Receive within 3 hours a quote on business days

  • 1. Product request

  • 2. Your information

General contact

Driemanssteeweg 190
3084 CB Rotterdam
The Netherlands
GMS Instruments Office