GMS Instruments Header Containers

Gasdetectie

Riken Keiki

FI-900 Gas Analyzer

The Riken Keiki FI-900 Optical interferometric gas analyser is equipped with a high-reliability optical interferometric sensor. Measurement principle: The gas concentration is detected from the amount of movement of interference fringes that occur due to the difference in the refractive indexes of the sample gas and reference gas. The FI-900 gas analyzer has enhanced self-diagnostic functions to constantly monitor 10 self-diagnostic parameters while diagnosing operating conditions of the device or its usage environment.

Prijs en bezorgtijd worden verstrekt op aanvraag
Sampling method Suction type
Principle of detection Interferometer Method
Explosion protected construction Flameproof enclosures
Approvals Japan Ex, ATEX, IECEx
Power source 24 VDC±10 %
Dimensions 286 (W) x 453 (H) x 150 (D) mm
Weight 23kg
Operating temperature range -20...60℃
Operating humidity range 0...95 %RH

The Riken Keiki FI-900 Optical interferometric gas analyser is equipped with a high-reliability optical interferometric sensor. Measurement principle: The gas concentration is detected from the amount of movement of interference fringes that occur due to the difference in the refractive indexes of the sample gas and reference gas. The FI-900 gas analyzer has enhanced self-diagnostic functions to constantly monitor 10 self-diagnostic parameters while diagnosing operating conditions of the device or its usage environment.

The Riken Keiki FI-900 is compatible with Modbus communications to constantly monitor not only gas concentrations but also the state of the measurement device. Log data is also recorded on the measurement device and can be checked to identify causes quickly on-site if faults occur with the device. Explosion-proof ATEX/IECEx/Japan Ex. Target industries: Hydrogen production (hydrogen purity measurement), Petroleum refining (hydrogen concentration measurement during hydrodesulfurization process), Petrochemicals (VCM and other process gas concentration measurement), etc.

Target gas:

1,3-Butadiene, 2,3,3,3-Tetrafluoroprop-1-ene, Acetone, Acetonitrile, Acrylonitrile, Ammonia, Benzene, Carbon Dioxide, Cyclohexane, Cyclopentanone, Deuterium, Dichloromethane, Dimethyl ether, Ethane, Ethanol, Ethyl Acetate, Ethylcyclohexane, Ethylene, Hydrogen, Isoprene, Isopropyl Alcohol, Methane, Methanol, Methyl ethyl ketone, Methyl isobutyl ketone, Methyl methacrylate, Methylcyclohexane, n-Butyl acetate, n-Heptane, n-Hexane, n-Propyl acetate, Octafluoropropane, Propane, Propylene, R-454C, Styrene, Sulfuryl fluoride, Toluene, Trichloroethylene, Vinyl chloride, Xylene

Vraag offerte aan

ONTVANG BINNEN 3 UUR EEN OFFERTE

  • 1. Product verzoek

    • or
  • 2. Jouw gegevens

  • Dit veld is bedoeld voor validatiedoeleinden en moet niet worden gewijzigd.
GMS_Instruments_Gas_Detector_Calibration_Riken Keiki_GX_8000

Want more information?

Get in touch with Sebastian our Riken Keiki Specialist

Sebastian

Sebastian Kelderman

Sales Representative

GMS-Instruments-Catalogus-01-2021-Cover

Product Catalogus

  • Download onze nieuwste product catalogus
  • Download

Contactgegevens

Driemanssteeweg 190
3084 CB Rotterdam
The Netherlands
GMS Instruments Office