Building on a strong tradition of innovative thinking, SIEMENS has designed the next generation of Coriolis flowmeters for excellence in performance, safety and user-friendliness: the SIEMENS SITRANS FC430. The digitally based SITRANS FC430 flowmeter features market-leading compactness, very high accuracy of 0.1%, low-pressure loss, extremely stable zero point and best-in-class data update with 100 Hz high-speed signal transfer.
Sizes | DN15 (½"), DN25 (1"), DN50 (2") |
---|---|
Repeatability | ±0.05 % |
Flow range (water @ 1 bar pressure loss) | DN15: 3700 kg/h (8157 lb/h) |
" | DN25: 11500 kg/h (25353 lb/h) |
" | DN50: 52000 kg/h (114640 lb/h) |
Display | Full graphical display, 240 x 160 pixels |
Power Supply | 24 to 90 V DC, 100 to 240 V AC |
Weight | 4,6 - 27 kg |
Materials | Stainless steel, Aluminium with corrosion-resistant coating |
Enclosure rating | IP67 |
Pressure ratings | Measuring tubes (100 bar), Sensor enclosure (17...20 bar), Sensor enclosure burst pressure (160 bar) |
Temperature ratings | -50…200°C (-58 … 392 °F) |
Building on a strong tradition of innovative thinking, SIEMENS has designed the next generation of Coriolis flowmeters for excellence in performance, safety and user-friendliness: the SIEMENS SITRANS FC430. The digitally based SITRANS FC430 flowmeter features market-leading compactness, very high accuracy of 0.1%, low-pressure loss, extremely stable zero point and best-in-class data update with 100 Hz high-speed signal transfer.
Unique support tools provide direct access to all operational and functional data, certificates and audit trails. The SITRANS FC430 is amongst the first Coriolis flowmeters to offer SIL 3 certification on the system, meeting the highest safety and reliability standards.
With the SITRANS FC430, process optimisation has never been easier – or more innovative. The complete flowmeter system SITRANS FC430 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R117 (Liquids other than water). All compact variants can be validated and configured for SIL2 or SIL3 operation as standard. SIL3 operation requires two flowmeters in series and monitored by a SIL rated control system.
The flowmeter is based on the latest developments in digital signal processing technology – engineered for high measuring performance:
FC430 is available as standard with 4-20 mA analogue output with HART 7.2. Additional input/output functions can be freely configured for analogue, pulse, frequency, relay or status. The transmitter comes with a user-configurable graphical display and new SensorFlash® technology, a micro SD card for configuration backup, firmware update and data storage. The SITRANS FC430 flowmeter system consists of a SITRANS FCS400 sensor and a SITRANS FCT030 transmitter.
Datasheet SIEMENS SITRANS FC430 | Datasheet-SIEMENS-SITRANS-FC410-Flow-System |
---|
RECEIVE A QUOTE WITHIN 3 HOURS ON BUSINESS DAYS