GMS Instruments Header Containers

Doorstroming

SIKA

VMM65 Magnetic Inductive Flow Sensor

The induQ® SIKA VMM65 magnetic inductive flow sensor is because of its robust design suitable for use in harsher ambient conditions. The steel fitting is entirely welded and therefore extremely stable and insensitive to interference.

Prijs en bezorgtijd worden verstrekt op aanvraag
Nominal diameter DN 65
Flow velocity range [m/s] 0.25...10
Volumetric flow range [m³/h] 3...119.5
Accuracy ±0.5 % of reading
Repeatability ±0.15 % of reading
Medium / min. conductivity of medium Water and other conductive liquids / 50 μS/cm
Medium temperature "
Hard rubber 0...90 °C
PTFE -20...100 °C at 40 bar -20...150 °C at 25 bar -20...180 °C at 16 bar
Process connections steel Min. -10 °C
Process connections, stainless steel Min. -20 °C
Pulse rate (factory-set) [1/m³] 1000
Operating range 0...20 mA / 4 ... 20 mA, selectable
Alarm output 2
Power supply 230 VAC -15 % / +10 %, 50/60 Hz 18...36 VDC
Electrical connection Electrical connection Plug connector M20 x 1.5
Degree of protection IP67

The induQ® SIKA VMM65 magnetic inductive flow sensor is because of its robust design suitable for use in harsher ambient conditions. The steel fitting is entirely welded and therefore extremely stable and insensitive to interference.

The available nominal diameters from DN 32 to DN 200 cover measurement requirements for average flow rates of up to 10 m/s. The large selection of high-quality materials provides for numerous application possibilities. Earth electrodes are available as an option. Besides, the SIKA VMM65 magnetic inductive flow sensor is available in both separate and compact design and is generally delivered with a calibration certificate. The electronic display allows customer-specific sensor configuration to meet the particular requirements on site.

The smart flow sensors of the induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes.

Vraag offerte aan

ONTVANG BINNEN 3 UUR EEN OFFERTE

  • 1. Product verzoek

    • or
  • 2. Jouw gegevens

  • Dit veld is bedoeld voor validatiedoeleinden en moet niet worden gewijzigd.
GMS Instruments IMPA Catalogus SIKA Industrial Thermometer type 297

Want more information?

Get in touch with Christiaan our flow expert

Christiaan

Christiaan van Mourik

Project-/ Accountmanager

GMS Instruments Catalog Cover

Product Catalogus

  • Download onze nieuwste product catalogus
  • Download

Contactgegevens

Driemanssteeweg 190
3084 CB Rotterdam
The Netherlands
GMS Instruments Office